Glacier Bay F1AA0005OB Installation Guide Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
Care and Cleaning
Troubleshooting
Clean periodically with a soft cloth.
This faucet is designed for years of trouble-free performance. Keep it looking new by doing the following:
Avoid abrasive cleaners, steel wool, and harsh chemicals as these will dull the nish and void your warranty.
Problem Possible Cause Solution
Hot and cold are reversed. Lines reversed or cartridge
installed upside down.
Rotate the cartridge stem 180°
so that the notch is facing down
towards the drain.
There is no or a low water
ow.
One or both water supplies are
not turned on.
Turn both water supply valves
counterclockwise to the on
position.
There is leaking or dripping
from the spout.
Grommets not sealing properly. Replace the cartridge.
There is only hot water or only
cold water from the spouts.
Balancing spool stuck. Replace the cartridge.
Water comes out of the show-
erhead during tub ll mode.
The pipe is incorrect.
The distance between the valve
and the showerhead is less than
46 in.
There are too many elbows or
something else that is restrict-
ing the ow of water exiting the
valve.
There is a restriction between
the valve and the tub spout.
The valve is installed upside
down.
Change the pipe to IPS or copper.
The distance from the shower-
head and valve moved to at least
46 in.
Change or remove anything
restrictive.
Remove the tub spout and ush
out debris and/or replace the
undersized line or ttings.
Remove the valve and reinstall it
using the correct orientation.
The temperature range is
restricted.
The handle (more common in
knob models) is installed upside
down.
Temperature limit stop is out of
position.
Remove the handle, rotate it
180°, and re-install.
Reposition the temperature limit
stop to the desired temperature
position.
Unable to install the handle or
the handle rubs against the
escutcheon.
The valve is installed too far
back from the nished wall.
Contact the Customer Service
Team and 1-855-HD-Glacier for
assistance.
The handle is hard to turn. The cartridge stem is difcult
to rotate.
Replace or lubricate the car-
tridge.
12
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 27 28

Comments to this Manuals

No comments